To meet the needs of extension, a power/clock/trigger distribution & synchronization module is provided. It supplies DC power, clocks, and trigger distribution to other measurement and control modules, ensuring good synchronization between the output/input channels of each module. The module offers up to 12 channels of 48V DC output, 12 channels of reference clock distribution, and 12 channels of trigger signal distribution.
19-inch standard 1U rack, providing support for 12 sets of equipment expansion;
Supports lockable AC power input, up to 3200 W;
Supports 12 channels of DC power output interfaces at 250 W @ 48~52 V;
Supports 12 channels of SMA 50 ohm reference clock output interfaces;
Supports 1 channel of SMA 50 ohm reference clock input;
Supports 1 channel of SMA high-impedance trigger signal input;
Supports RJ-45 Gigabit Ethernet communication control interface;
Supports monitoring of device status.
Supports 12 channels of SMA high-impedance trigger signal output interfaces;